Bard Lubri-Sil Two-Way Pediatric Foley Catheter with 3cc Balloon Capacity

Bard Lubri-Sil Two-Way Pediatric Foley Catheter with 3cc Balloon Capacity

Brand/Manufacturer: BARD INC
Hpfy stores Save
  • Prescription required
  • FSA Approved
  • Latex Free

Bard Lubri-Sil Two-Way Hydrogel Coated Pediatric Foley Catheter with 3cc Balloon Capacity creates a cushion between the catheter surface and the delicate urethral tissue, reducing friction and improving patient comfort. The lubricious catheter surface allows for smoother insertion. 

Item # Desc Pkg Price
175808 8FR Each
$20.05
$14.29
175808 8FR 12/Case
$222.95
$171.49
175810 10Fr Each
$20.09
$14.29
175810 10Fr 6/Pack
$117.59
$83.99
175810 10Fr 12/Case
$215.79
$165.99

Bard Lubri-Sil Pediatric Foley Catheter Features

  • Enhances safety and comfort for latex sensitive patients
  • 100% latex-free silicone catheter
  • Clear construction permits visualization of mucous build-up, clots, and initial urine flow
  • Lubricious catheter surface allows for smoother insertion

Inflation/Deflation Guidelines

  • Catheter Inflation:
    - Ensure that the Bard Foley catheter balloon is positioned well within the patients bladder. Slowly, with a gentle, constant force, inflate the Bard Foley catheter balloon with the volume prescribed on the package
    - Note that the 5cc balloon must be inflated with between 9cc to 10cc of sterile water
    - Improperly inflated Bard Foley catheter balloons may cause drainage and deflation difficulties
    - Using fluid other than sterile water may cause the balloon not to empty properly, especially after long dwell times

  • Catheter Deflation:
    - Select a luer slip syringe
    - Slide the plunger of the syringe up and down the barrel of the syringe several times to loosen it up
    - Compress the plunger all the way and then pull back the plunger slightly so that it does not adhere to the front of the syringe barrel
    - Gently insert the syringe in the catheter valve
    - Do not use more force than is required to make the syringe stick in the valve
    - Allow the pressure within the balloon to force the plunger back and fill the syringe with water
    - If you notice slow or no deflation, re-seat the syringe gently. Once again, allow the balloon to deflate slowly on its own
    - If the balloon does not deflate, reposition the patient.
    - Ensure that the catheter is not in traction, the proximal end of the catheter is not compressed within the bladder neck
    - Ensure that urine flows freely
    - Attempt to deflate the balloon by using the pressure in the balloon to force water into the syringe as described above
    - If the balloon stills fails to deflate, apply very gentle slow aspiration. Aspiration that is too rapid, or too forceful, may cause the inflation lumen within the Foley catheter to collapse
    - If permitted by hospital protocol, the valve arm may be severed
    - If this fails, contact an adequately trained professional for assistance, as directed by hospital protocol

Specification

Particulars Specifications
Gender Pediatric
Catheter Coating Hydrogel Coated
Catheter Style Coated Catheters
Catheter French Size 8FR,10FR
Ballon Size (CC) 3cc

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close