Rochester UltraFlex Self Adhering Catheter

Rochester UltraFlex Self Adhering Catheter

Brand/Manufacturer: ROCHESTER MEDICAL
Hpfy stores Save
  • FSA Approved
  • Latex Free

Utraflex Condom Catheter consists of a silicone construction that provides excellent breathability. The UltraFlex Male External Catheter has adhesive on its inner ring that holds the catheter in its place. It helps treat male incontinence and easily rolls over the penis. This self-adhering male external catheter is 100% latex-free. It offers maximum wear time. UltraFlex offers a built-in adhesive band in a length and placement typical of traditional male external catheters. It can be used to drain urine into a connected urinary bag.

5 Benefits of UltraFlex Male External Catheter

  • Kink-resistant
  • Soft silicone material
  • Latex-free
  • Easy to wear
  • Clear sheath for easy inspection of skin

Item # Desc Pkg Price
33101 Small (25mm) Each
$2.72
$1.75
33101 Small (25mm) 10/Pack
$25.02
$16.14
33101 Small (25mm) 50/Pack
$124.99
$80.63
33101 Small (25mm) 100/Pack
$178.05
$147.30
33102 Medium (29mm) Each
$2.86
$1.85
33102 Medium (29mm) 10/Pack
$25.02
$16.14
33102 Medium (29mm) 50/Pack
$124.99
$80.63
33102 Medium (29mm) 100/Pack
$203.00
$130.97
33103 Intermediate (32mm) Each
$2.63
$1.70
33103 Intermediate (32mm) 10/Pack
$25.02
$16.14
33103 Intermediate (32mm) 50/Pack
$124.99
$80.63
33103 Intermediate (32mm) 100/Pack
$174.15
$144.08
33104 Large (36mm) Each
$2.67
$1.72
33104 Large (36mm) 10/Pack
$25.02
$16.14
33104 Large (36mm) 50/Pack
$124.99
$80.63
33104 Large (36mm) 100/Pack
$211.49
$159.13
33105 Extra Large (41mm) Each
$2.66
$1.72
33105 Extra Large (41mm) 10/Pack
$25.02
$16.14
33105 Extra Large (41mm) 50/Pack
$124.99
$80.63

Features of UltraFlex Self-Adhering Catheter

  • Clear sheath for easy visual inspection of skin
  • Helps treat male incontinence
  • Latex-free external catheter to prevent allergic reactions
  • Five diameter sizes to provide superior patient comfort, proper fit and greater reliability
  • Breathable, odor-free, silicone design
  • Length and placement typical of traditional male external catheters
  • Kink proof funnel helps ensure uninterrupted urine flow
  • All-silicone material is clear and breathable

What to buy with UltraFlex Condom Catheter


When to use Rochester Condom Catheter?

It is recommended to use UltraFlex Condom Catheter if you have the following problems:
  • Urinary tract infection
  • Uncontrollable urinary frequency
  • Reflexive voiding from spinal cord injuries
  • Urethral trauma
  • Limited access to the toilet from dementia, impaired vision, or decreased mobility
  • Damage to sphincter from prostatectomy

How to use UltraFlex Self-Adhering Condom Catheter?

How to select the right size of Rochester External Catheter

Select the proper size of the catheter by using the Rochester Medical sizing guide. Place the sizing guide across the shaft of your penis to find the appropriate size. For comfort and effectiveness, choose the size closest to your the width of your penis.

 
Things you will need while applying an External Catheter

Things you need to have include the catheter, a collection bag with connecting tube, non-pointed manicure scissors, soap (avoid using soaps that leave a cream or residue on the skin), washcloth and towel.

 
How to prepare the patient while putting on external condom catheters

Do remember to wash your hands before beginning to reduce the risk of infections. Trim hairs on the shaft and base of your penis, and any other pubic hair that might interfere with the adhesive on the catheter

 
Cleansing the area before applying UltraFlex Condom Catheter

In order for the catheter adhesive to perform properly, the skin must be clean and very dry. Before application wash your penis with mild soap and warm water. Make sure that the area is completely dry before proceeding.

 
How to apply the Rochester UltraFlex Condom Catheter

Place the rolled self-adhering catheter over the penile tip. Unroll the catheter slowly and carefully, leaving just enough space in the funnel end so the tip of your penis does not rub against the inside of the funnel. If uncircumcised, be sure to leave the foreskin in place over the head of the penis.

 
Checking the seal on Rochester UltraFlex External Male Catheter

Smoothen any wrinkles in the catheter. Gently squeeze the catheter to properly to seal it to the skin. Wear time may be significantly reduced if adhesive is not properly sealed. Note: Too many wrinkles in the catheter may indicate that an inappropriate size has been selected. A smaller catheter may be more effective.

 
Attaching the Urinary Drainage Bag to Rochester UltraFlex Condom Catheter

Strap the urine collection bag to your thigh or calf, depending on your activities and your clothing. Connect one end of the tubing to the catheter and cut the tubing to a comfortable length. The tubing should not exert unnecessary pressure on the catheter. Connect the cut end to the leg bag. Always empty your leg bag before it becomes uncomfortably full and pulls on the catheter.

 
Rochester Male Condom Catheter Change Cycle

Wear time will vary from user to user. For proper hygiene it is recommended that the Rochester Male External Catheter must be changed every 24 hours.

 

How To remove the Rochester UltraFlex Male External Catheter?

Steps to remove the Rochester UltraFlex Condom Catheter

Clamp the connecting tube closed before removing the leg bag. Release the leg straps and disconnect the tubing at the top of the bag. Gently roll the external catheter forward and off the penis. To help loosen the adhesive prior to removal, apply a warm wet compress (such as a wet washcloth) around the catheter.

 

Specification

Catheter MaterialSilicone
Catheter Size25mm,29mm,32mm,36mm,41mm

Adhesive Type

Self-Adhesive

Material

Silicone

Kink-Resistant

Yes


Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopcatheters.com

Close